Mesopotamian Journal of Artificial Intelligence in Healthcare
Abstract
Small intracranial aneurysms (<3 mm) in Time-of-Flight MR angiography (TOF-MRA) are frequently missed by automated methods, although the overall performance metrics may not reveal this limitation. A nnU-Net pipeline with a Frangi vesselness channel is built on the ADAM benchmark and evaluated against an identically-configured baseline that differs only in foreground sampling. Lesion sensitivity for <3 mm aneurysms are 0.41–0.47 versus 0.65–0.76 for larger lesions, a size-stratified analysis exposes the gap. The gap is shown to be closed neither by focal loss nor by per-lesion-balanced (foreground) oversampling that substantially increases small-lesion training exposure, indicating a low signal-to-noise ratio rather than an exposure one. At matched sensitivity, however, per-lesion sampling substantially improves segmentation quality: on 5-fold cross-validation over all 93 ADAM subjects it more than halves false positives (0.26 vs 0.58 per case), improves Dice (0.582 vs 0.542) and HD95 (7.73 vs 15.07 mm), at comparable lesion sensitivity (0.667 vs 0.679). These scores also exceed the published nnU-Net-with-vessel-information benchmark (∼0.54 Dice, 0.53 sensitivity).
Recommended Citation
Prasanna, U M; Harish, B S; and Roopa, C K
(2026)
"Per-Lesion-Balanced Oversampling for Small Intracranial Aneurysm Segmentation in magnetic resonance angiography,"
Mesopotamian Journal of Artificial Intelligence in Healthcare: Vol. 4:
Iss.
1, Article 13.